Ultra 4
Ultra 4 Features
Non-contacting ultrasonic level control and flow measurement
Ultra 4 offers the sophistication and advanced features of the rest of the Ultra range in a compact, cost effective package and useful new features that make it even easier to set up and fine-tune. Offering as the name suggests, four alarm or control relays (3 X SPCO isolated and 1 x SPNO solid state) and a multi-functional display while loosing none of the easy set up and configuration that has made the Ultra range the natural choice for non-contacting measurement world-wide.
Like the rest of Pulsar's 'transducer plus controller' ranges, Ultra 4 is compatiable with both dB ultrasonic and dBR radar transducers. Ultra 4 can be wither wall or fasica mounted and includes HART, Profibus and Modbus digital communications options and the convenience of on-board micro SD card slot for extended data logging. Like the rest of the Ultra range, Ultra 4 also offers built in volume calculations based on standard tank shapes as well as advanced pump control and open channel flow measurement functions.

Main Screen
Ultra 4 allows the onboard relays to be configured a choice of four behaviours. The bar graph to the left hand side of the screen gives an indiciation of level, as well as a percentage shown underneath.

Trend Screen
Shows you at a glance how levels have varied over time. Ultra 4 is supplied complete with an 8GB Micro SD card to increase data logging capacity.

Echo Screen
Displays the echo profile without the need to plug in an external device. Pulsar's DATEM software is without equal in identifying and isolating the target, but the echo profile can help in fine-tuning and improving your measurement.
Contact Greyline Instruments for specific recommendations in your application.
dBMACH3
dBMACH3 Features

- 0 - 7.95 ft measurement range (0 - 2.425 m)
- ±1mm accuracy
- ±0.5 resolution
- IP68/NEMA 6P
- ATEX Zones 1 & 2 approval standard. ATEX Zone 0 optional
Non-contacting ultrasonic transducers for flow applications
Pulsar's full range of ultrasonic transducers can be used for flow measurement however, THE dBMACH3 has been specially created for flow applications.
The dBMACH3 is the first ultrasonic transducer with zero effective blanking distance.
Please contact Greyline if you need more information or for advice in your application. We can provide quotations and refer you to the Greyline sales representative in your area.
PC Suite
PC Software Suite

Interface for all your Pulsar equipment from a single installation
Pulsar's PC Suite now includes every major piece of Pulsar software in a single, convenient downloadable package. Activated by a security 'dongle' after the 30 day evaluation period and can be installed on multiple computers.
PC Suite can be used to set-up, calibrate, clone or download data from the main range of Pulsar equipment, particularly the recording and playback of echo traces from dB transducers.
Included within PC Software Suite

- IMP PC - set-up, program, calibrate, clone and configure IMP+ and IMP Lite units
- Blackbox PC - ability to create a programming template to easily set-up multiple Blackbox units, configure interfaces and outputs and to download data (depending on Blackbox unit in use)
- Ultra PC - ability to set-up single or several Ultra 3 or Ultra 5 units, view live DATEM echo processing traces and view data log information
- Twin PC - the same as Ultra PC but controls Pulsar's two-channel device, UltraTWIN
- Sludge Finder 2 PC - control, program and calibrate Pulsar's sludge interface monitor, Sludge Finder 2. Also includes capability to program separate RAS and FLOC levels, see interface level profiles and store level data
- dBi HART PC - address and configure the Pulsar's dBi HART Intelligent Transducers
Please contact Greyline if you need more information or for advice in your application. We can provide quotations and refer you to the Greyline sales representative in your area.
Downloads
Document Name |
Description |
Download |
Ultra 4 Datasheet |
Ultra 4 Flow Meter Datasheet |
Download >> |
Ultra 4 Manual |
Ultra 4 Instruction Manual |
Download >> |
dBMACH3 Brochure |
dB Series Transducers Product Guide |
Download >> |
dBMACH3 Datasheet |
dBMACH3 & dB3 with Double Sun Shields Datasheet |
Download >> |
dBMACH3 Manual |
dB Series Transducers Instruction Manual |
Download >> |
PC Suite Brochure |
Pulsar PC Suite Software Brochure |
Download >> |
PC Suite Software |
3.1 - hardware dogle to license updated 03-09-2015 |
Download >> |
Case Studies
Title |
Description |
Download |
Ultrasonics more accurate than radar – it’s official |
There are many independently tested open channel flow measurement MCERTS devices on the market. |
Read More... |
Pulsar's Non-contacting Measurement and Control Suits Center Parcs |
Pulsar Process Measurement has supplied a range of non-contacting instruments to monitor and control dosing plant and a pumping station to Center Parcs Woburn Forest in Bedfordshire and also measure open channel flow of influent, adding to the... |
Read More... |
Successful Track Record Makes Pulsar The Right Choice For Veolia Water |
Sanquhar is a small town in Dumfries and Galloway, mostly famous for having what may well be the oldest post office in the world, and for defining the rules of the sport of curling. For non-contacting ultrasonic level measurement equipment... |
Read More... |